Integration
333587D
75
56
Pump Heartbeat To PLC
Boolean
0
1
0
56
A
57
Automation Control Ready
Boolean
0
1
1
A
58
System Active
Boolean
0
1
2
A
59
Pump PLC Lockout/Control Active
Boolean
0
1
3
A
60
No Alarms are Present
Boolean
0
1
4
A
61
No Deviations are Present
Boolean
0
1
5
A
62
No Advisories are Present
Boolean
0
1
6
A
63
System Ready to dispense
Boolean
0
1
7
A
64
Pre-charge / De-charge Active
Boolean
0
1
0
57
A
65
Dispense In Process
Boolean
0
1
1
A
66
Drum Is Low
Boolean
0
1
2
A
67
Drum Is Empty
Boolean
0
1
3
A
68
Pump Not Primed
Boolean
0
1
4
A
69
Pump in Job Cycle
Boolean
0
1
5
A
70
Prime Active
Boolean
0
1
6
A
71
Valve Depressurization Active
Boolean
0
1
7
A
72
Platen Depressurization Active
Boolean
0
1
0
58
A
73
Auto Depressurization Active
Boolean
0
1
1
A
74
Auto Depressurization Happened
Boolean
0
1
2
A
75
Pump is trying to move
Boolean
0
1
3
A
76
Pump is actually moving
Boolean
0
1
4
A
77
Dispense Valve Opened
Boolean
0
1
5
A
78
Platen Valve Opened
Boolean
0
1
6
A
79
Tandem Active Pump (Tandem System only)
(0 = Pump 1, 1 = Pump 2)
Boolean
0
1
7
A
80
E-Flo iQ Mode Active
Boolean
0
1
0
59
A
81
Changeover Occurred during Dispense
Boolean
0
1
1
A
82
Reserved Bit 1
Boolean
-
-
2
A
83
Reserved Bit 2
Boolean
-
-
3
A
84
Reserved Bit 3
Boolean
-
-
4
A
85
Reserved Bit 4
Boolean
-
-
5
A
86
Reserved Bit 5
Boolean
-
-
6
A
87
Reserved Bit 6
Boolean
-
-
7
A
88
Actual Pump Flowrate (xxxx cc/min)
uint16
0
6000
0-14 60-61
A
89
Outlet Pressure (xxx.x bar)
uint16
0
413.6
0-14 62-63
A
90
Pump Data Exchange Element Feedback
uint16
0
32767
0-14 64-65
A
E-Flo iQ Maps 18E218 and 18E224
Automation INPUTS (signal from E-Flo iQ to PLC)
Instanc
e ID
Description
Data
Type
Min
Value
Max
Value
Bit
Byte
Heat