Alarms
3A8848A
39
Alarms
Any time a Fault / Warning occurs, a combination of LED’s illuminate to notify that there is a problem and to help
identify the kind of Fault / Warning that occurred.
• Faults will not automatically clear. Warnings will clear after a set time, if condition was fixed.
• To clear a fault, press and hold the RESET button on the display button pad for 3 seconds.
• To clear a warning instantly, press and immediately release the RESET button.
The following pages describe the most likely fault / warnings.
Alarm Type
What it Looks Like
What it Indicates
Solution
Low Level
Warning
Level of lubricant in
reservoir is low and addi
-
tional lubricant needs to be
added.
Unit continues to operate
as normal for a limited
period of time until a low
level alarm is triggered.
Add lubricant to reservoir.
After lubricant
is added,
press the
RESET but
-
ton to clear the warning.
Low Level
Fault
Level of lubricant in
reservoir is low and addi
-
tional lubricant needs to be
added.
Unit stops pumping and
displays amount of accu
-
mulated time since the
alarm was triggered.
Add lubricant to reservoir.
After lubri
-
cant is
added press
and hold the
RESET button to clear
fault.
If repriming pump is
required, the low level
alarm time should be
decreased. See A-2:
Advanced Programming,
Low Level Alarm Time
page 32.