Run Mode
3A8848A
37
Run Mode
Time Control
After setup is complete, the G5 automatically begins to
run the OFF Time sequence (F
• The G5 runs the programmed OFF sequence.
(Notice the OFF Time LED on the display lights and
the OFF Time counts down on the display.)
• The example shown in F
. 31 shows an OFF Time
of 1 hour and 32 minutes before the lubrication
cycle begins.
• When the OFF Time count reaches zero, the G5
Automatic Lubrication Pump turns the pump on
and it runs for the programmed ON Time cycle (F
32).
(Notice the ON Time LED is now illuminated on the
display.)
• The example shown in F
. 32 shows an ON Time
of 8 minutes and 42 seconds before the lubrication
cycle ends.
• When the ON Time count reaches zero, the pump
shuts off again and the system again runs OFF
Time cycle and the OFF Time LED is now again illu
-
minated (F
. 31).
This sequence repeats itself until the device is
reprogrammed or an alarm occurs.
Manual Run Cycle
To run an extra (non-programmed)
lubrication cycle, push the Manual Start
button.
F
IG
. 31
ON
OFF
!
HH
MM
SS
##
MM : SS
HH : MM
F
IG
. 32
ON
OFF
!
HH
MM
SS
##
MM : SS
HH : MM