Advanced Programming
3A8848A
31
Advanced Programming
There are several Advanced Programming options. The following Table identifies each option and when it is used.
Advanced
Option
Setting
Format/ Description
Why Use This?
A1
Lockout
Code (Optional)
Secures setup modes with
PIN
Prevents unauthorized users to adjusting settings.
A2
Low Level Alarm
Time
MM:SS
(minutes:seconds)
sets amount of time
between Low Level Warning
to Low Level Fault.
Default = 3 minutes
To accommodate most lubrication situations, a con
-
servative amount of time is programmed between
the low level warning and fault to help protect unit
from running dry. If necessary the amount of time
the unit runs before stopping due to a low level fault
can be adjusted.
A5
Active Alarm
Changes alarm output
behavior.
Default = OFF
Uses alarm output to determine if a unit has an
alarm AND/OR loses power.
The output turns ON when power is applied. It turns
OFF when power is lost or an alarm occurs.
Normal operation (OFF) will only activate alarm out
-
put in an alarm condition when power is on.
Can change (set to ON) to activate alarm with power
ON and deactivate with power OFF OR warning.
Used to manage power outage.
A7
Constant Alarm
Output on Fault
Changes alarm output
behavior.
Default = OFF
This function changes the behavior of the alarm out
-
put in a fault from either toggling once every second
or steady on.
Firmware 6.02 and later
A8
4 Digit Hour Off
Time
Changes maximum OFF
time.
Default = OFF
This function changes OFF time from HH:MM to
HHHH. It allows a maximum of 9999 hours of OFF
time.
Firmware 6.04 and later for non-DMS models and 07.07 and later for DMS models
A10
Low Level Reset
Upon power ON
Changes low level fault
upon power ON.
Default = OFF
This function changes the behavior of the low level
fault upon power ON.
A11
Warning OFF
through alarm
relay
Changes alarm output
behavior.
Default = OFF
This function changes the behavior of the alarm out
-
put in a warning condition to always OFF.
Firmware 6.06 and later for non-DMS models and 07.09 and later for DMS models
A12
Prelube
Sequences
Changes the number of the
Prelube sequences.
This function changes the behavior of the prelube
function to add more lubrication sequences upon
pump start up.
A13
MM:SS Off Time Changes the OFF time pro
-
gramming from HH:MM to
MM:SS
Default = OFF
This function changes the programming of the OFF
time.