Operation
3A8848A
19
• Use these volume adjustments as a starting point,
then adjust as needed to ensure the desired
lubrication dispense.
Load Pump with Grease
To ensure optimal performance from the G5 pump:
• Use only NLGI #000 - #2 greases appropriate for
the application, automatic dispensing, and the
temperature. Consult with the machine and lube
manufacturer for details.
• The reservoir can be filled using a hand operated
pump, a pneumatic pump, or an electric transfer
pump.
• Do not overfill the reservoir.
• Do not operate the G5 pump without a reservoir
attached.
Models Without a Follower Plate
1. Connect the fill hose to the Zerk inlet fill fitting
. 12)
2. For higher viscosity fluids, start the pump to rotate
the stirring paddle during the fill to prevent air
pockets from forming. Do not exceed a 30 minute
run time.
For models using an external controller, start the
pump operation following your controller
specifications.
3. Fill the reservoir with NLGI grease.
NOTE:
The vent port located in rear of reservoir should
not be used as an overfill port/indicator (F
4. Remove the fill hose.
NOTICE
• Always clean the fitting (D) (F
. 12) with a clean
dry cloth prior to filling the reservoir. Dirt and/or
debris can damage the pump and/or the lubrica
-
tion system.
• When changing greases, always use compatible
fluids or greases.
• Use care when filling the reservoir with a pneu
-
matic or an electric transfer pump, to not pressur
-
ize and break the reservoir.
F
IG
. 12
D