Run Mode
38
3A8848A
Additional Controls
Prelube / Prelube Delay
In all models a power OFF/ON cycle can be controlled
with the Prelube and Prelube Delay functions.
Prelube
The Prelube function has been selected. Prelube delay
is set to 00:00:
• Power to the unit cycles OFF then ON.
• Unit immediately begins a lubrication cycle.
• Pro Model - display shows ON Time (See
, page 37).
Prelube Delay
The Prelube function has been selected. Prelube delay
is set to something other than 00:00:
• Power to the unit cycles OFF then ON.
• Unit immediately begins the Prelube Delay
count down until the lubrication cycle begins.
• The LED next to the clock in the OFF field is
illuminated (F
. 33).
• The Prelube LED lights (F
. 33).
• The display shows time remaining until lubrica
-
tion cycle begins. The example shown in F
33 shows 8 minutes and 14 seconds left until a
lubrication cycle begins.
Manual Run Cycle
To run an extra (non-programmed) lubrica
-
tion cycle, push the Manual Start button.
NOTE
: Manual Run option is not available while unit is
in Vent Mode.
F
IG
. 33
ON
OFF
!
HH
MM
SS
##
MM : SS
HH : MM