Operation
3A8848A
25
Prime the Pump
NOTE:
It is not necessary to prime the pump each time
the pump is filled with lubricant. The pump only
requires priming the first time used, or if the pump is
allowed to run dry.
1. Loosen the pump element fitting using two
wrenches working in opposite directions (F
. 20).
2. Run the pump until air-free lubricant is dispensed
out of the element fitting (F
3. Tighten the pump element fitting using two
wrenches working in opposite directions (see F
20).
NOTICE
Make sure not to loosen the pump element when
loosening the pump element fitting. If the pump
element is loosened, this will change the output
volume.
F
IG
. 20
F
IG
. 21