Installation
12
3A8848A
Choose an Installation Location
• Select a location that adequately supports the
weight of the G5 pump and lubricant, as well as all
plumbing and electrical connections.
• Refer to the mounting hole layouts provided in the
, page 48. No other installation
configuration should be used.
• Use designated mounting holes and provided
configurations only.
• Always mount the G5 pump oil models upright.
• Mount top fill G5 pump models so there is a
minimum clearance of four (4) in. (10.2 cm) above
the reservoir to allow for lid removal and filling.
• If the G5 pump grease model is going to be
operated in a tilted or inverted position for any
period of time, use a model that includes a follower
plate, otherwise the G5 pump must be mounted
upright. Refer to the model number to confirm if a
follower plate was installed on the pump. See
Understanding the Model Number
, page 4, to
identify this character in the model number.
• Use the three included fasteners to secure the G5
pump to the mounting surface.
• Some installations may require an additional
reservoir support bracket. See the following table
for bracket information.
• In high vibration environments, additional isolation
at the mounting point is necessary. See the
following table for further information.
• AC pumps are not recommended when high
vibration or shock is present.
System Configuration and
Wiring
Grounding
If the product is permanently connected, it must be:
• installed by a qualified electrician or serviceman
• connected to a grounded, permanent wiring system
If an attachment plug is required in the end use
application:
• it must be rated for the product electrical
specifications
• it must be an approved, 3-wire grounding type
attachment plug
• it must be plugged into a properly installed and
grounded outlet in accordance with all local codes
and ordinances
• when repair or replacement of the power cord or
plug is required, do not connect the grounding wire
to either flat blade terminal
AUTOMATIC SYSTEM ACTIVATION HAZARD
The system is equipped with an automatic timer that
activates the pump lubrication system when power is
connected or when exiting the programming
function. Unexpected activation of the system could
result in serious injury, including skin injection and
amputation.
Before you install or remove the lubrication pump
from the system, disconnect and isolate all power
supplies and relieve all pressure.
Part No. Description
571159
Reservoir bracket and strap
125910
L-Bracket for pump
127665
USP to G-Series mounting bracket
132187
Isolator mounting kit
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Improper installation of the grounding conductor may
result in a risk of electric shock. This product must be
installed by a qualified electrician in compliance with
all state and local codes and regulations.