Operation
20
3A8848A
Models With a JIC Side Vent
1. Inspect the JIC vent and vent hose, if attached, to
make sure it is not plugged.
2. Connect the fill hose to the zerk inlet fill fitting (see
3. For higher viscosity fluids, start the pump rotating
the stirring paddle during the fill to prevent air
pockets from forming. Do not exceed a 30 minute
run time.
For models using an external controller, start pump
operation following your controller specifications.
4. Fill the reservoir with NLGI grease.
NOTE:
The JIC vent and vent hose, if attached, should
not be used as an overfill port/indicator (F
. 13).
5. Remove the fill hose.
Models with Top Fill
1. Disconnect the power from the equipment.
NOTE:
If battery disconnect is not available, remove the
power cord (F
. 14).
2. Clean the top of the lid and the area around the top
of the reservoir to ensure that no debris falls into
the reservoir when the lid is removed.
3. Turn the lid counterclockwise to remove.
4. Place the lid in a clean area to avoid debris getting
inside of the lid or on the threads.
5. Fill the reservoir with new clean grease.
F
IG
. 13
NOTICE
Check the JIC vent and vent hose, if attached, after
removal of the fill hose for any grease. Remove any
grease from the JIC vent and vent hose.
Grease in the hose may create a vacuum and cause
problems with pumping, or may cause excessive
pressure and cause damage to the reservoir.
JIC Vent
Vent Hose
AUTOMATIC SYSTEM ACTIVATION HAZARD
Moving parts can pinch, cut or amputate fingers and
other body parts.
• Keep clear of moving parts.
• Do not operate equipment with lid removed.
• Disconnect power before removing lid.
F
IG
. 14