Pro Model Setup
3A8848A
27
Pro Model Setup
Control Panel Overview (F
. 22)
NOTE:
Programming instructions begin on page 28.
F
IG
. 22
OFF TIME
•
LED lights when OFF Time sequence is running.
•
Value is entered in HH:MM.
•
Displays in HH:MM (hours and minutes) when > 1
hour.
•
Displays in MM:SS (minutes and second) when < 1
hour.
•
Times pump rest between cycles.
•
Counts down from set time to zero.
ON
OFF
!
HH
MM
SS
##
MM : SS
HH : MM
DISPLAY
•
A blinking LED under HH, MM, SS
or ## indicates type of measure
-
ment unit you are setting; i.e., HH is
hours.
•
A blinking number on the display
indicates the G5 is in SETUP
MODE.
•
In RUN MODE displayed numbers
count up or down. See Time ON
and Time OFF.
ON TIME
•
LED lights when ON Time
sequence is running.
•
Display shows time as
MM:SS (minutes and sec
-
onds). i.e., 08:30 is 8 min
-
utes: 30 seconds.
•
Times lubrication cycle.
•
Counts down from a set
time to zero.
ALARM ICONS
LED next to icon lights when a
fault / warning event occurs
during a run cycle. See page
39 for a complete description
of these alarm scenarios.
LOCK ICON
•
LED next to icon lights indi
-
cating PIN is required to
enter setup.
•
In SETUP MODE LED lights
when setting up the PIN.
PRELUBE
LED next to icon lights indicating
Prelube function is enabled.
LEFT DIRECTION ARROW /
RESET
•
In SETUP MODE: moves
cursor in display one field to
the left.
•
In RUN MODE: single press
clears warning.
•
In RUN MODE: pressing for
one second ends run cycle if
there are no warnings.
•
In ALARM MODE: pressing
and holding for 3 seconds
clears fault / warning and
switches cycle to OFF
MODE.
RIGHT DIRECTION ARROW /
MANUAL RUN / ENTER:
•
In SETUP MODE: saves entry,
moves cursor in display one
field to the right or to the next
setup step.
•
In RUN MODE: starts a manual
run cycle.
UP and DOWN ARROW
•
Hold both the UP and DOWN ARROW
buttons down together for 3 seconds
to enter SETUP MODE.
•
In SETUP MODE, increases or
decreases number values shown in
display.