Accessories
333347F
111
6 Channel Upgrade Kit Installation
1.
Disconnect plug from power outlet or turn off circuit
breaker for incoming power.
2.
Place grounding wrist strap (1303) over your wrist
and secure other end to a grounded surface.
3.
Set the kit’s MZLP (1301) rotary switch to “3”.
4.
Remove screws (BB) then remove plate (AA) from
system.
5.
Use screws (BB) to install MZLP (1301) onto sys-
tem.
NOTE:
The new MZLP (1301) will be referred to as
MZLP 3, and the original MZLPs that came with the sys-
tem will be referred to as MZLP 1 and MZLP 2 from here
on. See F
6.
Remove electrical enclosure front access door.
NOTE:
Do not force the electrical connection. Minimal
force is required to seat the connector. If resistance is
felt, stop and verify the connector orientation.
7.
Connect CAN jumper cable (1302) to MZLP 2 con-
nector J3 and connect other end of jumper
cable (1302) to MZLP 3 connector J3. See F
. 66.
8.
Install jumper connector (1307) in J5 on MZLP 3.
9.
Connect wires from power harness (1306) between
AWB connector J5 and MZLP connector J2.
10. Remove plugs (CC) from fluid manifold and replace
with straight fittings (1309), tee fittings (1308), or the
extra fittings included with the InvisiPac system.
Use the fittings that meet your hose routing needs.
11. To ensure your InvisiPac system has the latest soft-
ware, insert token (1306) into ADM. Follow
, page 77.
F
IG
. 66
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WLD
0=/3
0=/3
0=/3
Step 7: Install jumper cable (1302).