Accessories
102
333347F
System Stand, 24R088
Use the stand to mount the system at eye level. When
the system is mounted on the stand, the ADM is 45 in.
(1.14 m) above the bottom of the stand.
System Stand Installation
1.
Place stand (1001) in desired location.
2.
Use bolt holes to bolt stand in place.
3.
Place system on stand.
4.
Use screws and nuts to secure system to stand.
Caster for Stand, 120302
Caster with friction post mounts directly to
system stand using no extra hardware. Four
required. Casters raise stand an additional
4.25 in. (108 mm).
Adapter Plate, 24R083
Use this adapter plate to install InvisiPac in place of an
existing hot melt applicator system.
Adapter Plate Installation
1.
Remove existing hot melt applicator system.
2.
Use six screws (1102) and six nuts (1103) to secure
adapter plate (1101) through the existing holes from
the previous system.
3.
Align the InvisiPac system with the bolts on the
adapter plate (1101) then place onto the adapter
plate (1101).
4.
Use the remaining three nuts (1103) to secure the
InvisiPac system to the adapter plate (1101).
5.
Use elbow fitting (1104) to install system air inlet
filter (A, not included with kit).
Ref
Part
Description
Qty
1001
---
STAND
1
1002
112395 SCREW flange head cap
3
1003
112958 NUT, hex, flanged
3
WLD
1001
1003
1002
Ref
Part
Description
Qty
1101
---
PLATE, adapter
1
1102
112395 SCREW flange head cap
6
1103
112958 NUT, hex, flanged
9
1104
121283 FITTING, elbow, 45 degree
1
WLD
A
C
B
Bolt Hole Dimensions
A
9.8 in. (249 mm)
B
14.843-15.157 in.
(377.0-385.0 mm)
C
17.003-17.317 in.
(431.9-439.9 mm)
1101
1102
1103
1104
A
Summary of Contents for 24T918
Page 16: ...Component Identification 16 333347F ...