Technical Data
124
333347F
Main System Air Supply Pressure Range (set with
regulator on front of system)
80-100 psi
0.55-0.69 MPa (5.5-7 bar)
Pump Operating Air Pressure Range
20-100 psi
0.14-0.69 MPa (0.7-7 bar)
Pump Operating Fluid Pressure Range
240-1200 psi
1.7-8 MPa (17-80 bar)
Control Temperature Range
100-400°F
38-204°C
Ambient Temperature Range
32-120°F
0-49°C
Vacuum Transfer Specifications
Maximum Vacuum Transfer Hose Length
30 ft
9.1 m
Maximum Vacuum Transfer Hose Maximum Verti-
cal Rise
10 ft
3.0 m
Vacuum Transfer Operating Pneumatic Pressure
Range (set with regulator on front of system)
40-100 psi
280-690 kPa (2.8-6.9 bar)
Vacuum Transfer Air Consumption at 40 psi (280
kPa, 2.8 bar),
9.5 scfm (intermittent duty; 4% at
25 lb/hr)
16.1 scmh (intermittent duty; 4% at
11.3 kg/hr)
Vacuum Transfer Air Consumption at 80 psi (550
kPa, 5.5 bar)
17.2 scfm (intermittent duty; 4% at
25 lb/hr)
29.2 scmh (intermittent duty; 4% at
11.3 kg/hr)
Required Air Tubing Size
Minimum Air Tubing Inner Diameter (less than 50
ft, 15.2 m of tubing)
3/8 in.
9.5 mm
Minimum Air Tubing Inner Diameter (50 ft, 15.2 m
or longer of tubing)
1/2 in.
12.7 mm
Sound
Sound Pressure Level***
77 dB(A)
IP Code
InvisiPac Base System
IP54
Wetted Parts
Wetted Parts
PTFE, chemically resistant o-rings, aluminum, stainless steel, zinc plat-
ing, carbon steel, brass, carbide, chrome
Approvals and Standards
UL499, CSA88, CE, ISO
30 Gallon Vibrating Hopper
Required Air Pressure Supplied To 30 Gallon
Vibrating Hopper
100 psi
0.7 MPa (7 bar)
Air Consumption
17.1 scfm
29.1 cubic meters per hour
* From 70°F to 350°F (21°C to 177°C), dependant upon power supply and machine configuration.
** Excludes vacuum transfer tube, shaker assembly, and pellet storage bin.
*** Sound pressure level measured 3.1 ft (1 meter) from equipment.
InvisiPac Hot Melt Delivery System
US
Metric
Summary of Contents for 24T918
Page 16: ...Component Identification 16 333347F ...
Page 103: ...Accessories 333347F 103 ...
Page 129: ...Technical Data 333347F 129 ...