Troubleshooting
ADM Error Code Table
When an error occurs, press
to acknowledge the error. If a Maintenance error occurs, navigate to the Mainte-
nance screen and press
to clear the error.
The last digit of the error code indicates the melter, applicator (gun), or hose to which the error applies. The “_”
(underscore) character indicates the code applies to multiple items.
An alarm will disable the heating system and pump. A deviation or advisory will not disable the heating system and
pump.
To avoid injury due to unexpected machine operation
initiated by a remote controller, disconnect the cus-
tomer I/O cable from the system prior to troubleshoot-
ing.
Last Digit in Code
Code Relates to:
0
Melter
1
Applicator (Gun) 1
2
Hose 1
3
Applicator (Gun) 2
4
Hose 2
5
Applicator (Gun) 3
6
Hose 3
7
Applicator (Gun) 4
8
Hose 4
9
Applicator (Gun) 5
A
Hose 5
B
Applicator (Gun) 6
C
Hose 6
Code
Description
Type
Cause
Solution
A1D0
Low Current
Melter
Advi-
sory
Melter current is less than 500mA.
Faulty melter heater(s). Check heater resistance
and resistance to ground. Replace faulty
heater(s).
A1D_
Low Current
Gun X
Advi-
sory
Applicator current is less than 500mA.
Faulty applicator heater. Verify applicator heater
has a minimum wattage of 90 Watts at 240 VAC.
Check heater resistance and resistance to
ground. Replace faulty heater.
A1D_
Low Current
Hose X
Advi-
sory
Hose current is less than 500mA.
Faulty hose heater. Check heater resistance and
resistance to ground. Replace faulty hose.