Troubleshooting
333347F
53
Static shock
when touching
shaker or
adhesive bin.
Ground wire not in
place on shaker
assembly. Some adhe-
sives, flow rates, and
ambient conditions can
cause excessive static
buildup on the shaker
tube.
Attach a ground wire from the shaft of the shaker unit to a true earth
ground. Order shaker grounding kit 24R708.
Adhesive not
dispensing at
the correct
time.
Dispense modules
opening at the wrong
time.
InvisiPac system does not control the opening and closing of the appli-
cators. The separate controller needs to be adjusted. Consult pattern
control manufacturer or qualified electrician.
Pump and vac-
uum feed sys-
tem cycle on
and off before
temperature
setpoint is
achieved.
Solenoid connector is
installed into the light
tower plug on the
MZLP daughter board
Move solenoid connector from J12 (light tower) to J13 (solenoid
valves) on the daughter board on the MZLP.
Problem
Cause
Solution