Setup
26
333347F
11. On the Targets screen, adjust heated hose and
applicator temperature settings:
NOTE:
InvisiPac is a high powered tank-free system
that delivers heat faster than traditional tank systems.
Tanks are often run at a lower temperature than the
application temperature to avoid excessive adhesive
degradation since a large volume of adhesive sits at
temperature.
a.
Press
to select the channel.
b.
Use
and
, shown next to
, to
adjust applicator temperature setting to the
desired setting for that channel.
NOTE:
If a higher applicator temperature is desired,
adjust all zones to the higher temperature or adjust only
the applicator in small increments.
NOTE:
Alternatively, use the physical up and down
arrow push-buttons on the ADM keypad until
is
next to the temperature setting to change then use the
numeric keypad to enter the desired temperature.
c.
Use
and
, shown next to
,
to adjust heated hose temperature setting to the
desired setting for that channel.
NOTE:
Alternatively, use the physical up and down
arrow push-buttons on the ADM keypad until
is
next to the temperature setting to change then use the
numeric keypad to enter the desired temperature.
Applicators
Applicator heating is controlled by the system, but the
system does not control opening and closing the appli-
cators. Setup a separate pattern controller to open and
close the applicators.
NOTICE
Set melter, hose, and gun to the same setpoint
temperature for best performance. Do not set the
hose temperature higher than the melter. Running
the hose at a setpoint higher than the melter is
unnecessary in this tank-free system and could
lead to adhesive degradation in the hose. Short
adhesive residence time in the melter eliminates
the need to set the melter at a lower setpoint than
other zones.