Repair
60
333347F
Melter
Remove Melter Assembly
NOTE:
This only needs to be done when replacing
items that require access to the bottom of the melter
assembly.
1.
Perform
procedure on page 34
then wait for system to cool.
2.
Close the bleed type ball valve at the system air
inlet.
3.
Turn main power switch OFF.
4.
Disconnect all heated hoses from the melter outlet
manifold.
5.
Remove cable from ADM (30) then slide forward the
shroud (29) and remove it from the system.
6.
Remove screws (8) then remove electrical enclo-
sure front access door (10).
7.
Disconnect heater rod wires from J4 connector on
AWB board.
8.
Remove the air tube (36) from the relief valve (245).
Pull the air tube from the metal shroud (27).
9.
Remove nuts (3) on the back metal shroud (27)
then remove shroud.
10. Remove fabric melter insulator (53).
11. Loosen screw (AA) then remove sensor (125). See
F
IG
. 42, page 63.
12. Loosen hose clamp (81) then remove funnel (FF).
13. Remove wire connectors from the over-temperature
switch (251).
14. Remove insulators (53, 75) from the melter
assembly (5).
15. Disconnect the fill sensor cable from the fill
16. Disconnect the pump cycle sensor cable from the
air motor.
17. Remove the air tube from the air motor (218).
18. Loosen screw (AA) then remove sensor (125). See
19. Disconnect ground screw (87) and ring terminal (88)
from melter assembly.
20. Remove electrical enclosure front access door (10).
F
IG
. 39
WLD
FF
29
30
27
10
8
203
1
3
53
3
5
218
81
75
251
245
36
F
IG
. 40
WLD
87
88
Summary of Contents for 24T918
Page 16: ...Component Identification 16 333347F ...
Page 103: ...Accessories 333347F 103 ...
Page 129: ...Technical Data 333347F 129 ...