Maintenance
333347F
39
Filter Maintenance Guidelines*
* These recommendations are service level guidelines - actual service levels required in your factory will vary based
on environmental and operating conditions. High or low volume adhesive usage, as well as adhesives that contain a
powdered release agent or are otherwise dusty, will have an impact on the frequency of filter maintenance. To estab-
lish a preventative maintenance cycle tailored to your environment, Graco recommends inspecting filters every 4
weeks after installation and replacing when necessary. Document replacement intervals and use this as your preven-
tative maintenance schedule moving forward.
Environmental Classification
Clean
Moderate
Dusty
Pump inlet filter
Replace filter
every
six
months
Replace filter
every
four
months
Replace filter
every
two
months
Pump outlet filter
Applicator manifold filter
System air filter
Solenoid exhaust filters
Feed funnel filter
Feed funnel inspection/cleanout