Repair
333347F
63
Replace Band Heater Temperature Sensor
Disassembly (see F
IG
. 42):
1.
Close the bleed-type ball valve installed at the
system air inlet to relieve all air pressure in the
system.
2.
Turn main power switch OFF.
3.
Disconnect cable from ADM then remove shroud.
4.
Remove air tube (36) from relief valve. Pull the air
tube through the metal shroud (27).
5.
Remove nuts (3) then remove metal shroud (27).
See F
6.
Remove fabric melter insulator (53).
7.
Loosen screw (AA) then remove sensor (125).
8.
Remove electrical enclosure access door (10).
9.
Disconnect the temperature sensor cable from
MZLP connector labeled J5. See F
IG
. 42.
NOTE:
This connector also includes the over-tempera-
ture switch wires.
10. Disconnect wire connectors from over-temperature
switch (251). See F
11. Pull cable out of the electrical enclosure then dis-
card sensor (125) and wires.
Reassembly (see F
IG
. 42):
1.
Route new harness wires through grommet (63) in
the top of the electrical enclosure.
2.
Connect wire connectors to over-temperature
switch (251). See F
3.
Place band heater temperature sensor (125) in
melter.
4.
Tighten screw (AA).
NOTE:
Screw should lightly squeeze the temperature
sensor to hold it in place. It should not bend the sensor.
5.
Connect new harness to MZLP connector labeled
J5.
6.
Install electrical enclosure access door (10). See
F
7.
Install fabric melter insulator (53).
8.
Use nuts (3) to install metal shroud (27). See F
9.
Route relief valve air tube through the metal shroud
then attach to the relief valve.
10. Feed ADM cable through shroud then install shroud
and connect cable to ADM.
11. Turn main power switch ON.
12. Open system air inlet ball valve.
F
IG
. 42
WLD
AA
125
53
40
80
10