Setup
20
333347F
14. Install heated hoses, see F
a.
Place a rag on the drain tray (W2) attached to
the melter. Residual oil may be in the system
from the factory. See F
b.
Use a 1/4 in. allen wrench to remove the drain
port plug (W1). See F
NOTE:
A 1/4 in. allen wrench is shipped loose with the
system.
c.
When fluid stops draining, re-install drain port
plug (W1) then remove rag. See F
d.
Remove plug (247) from the lowest numbered
outlet on the melter. Do not use the drain
plug (W1). See F
. 11.
NOTE:
In the following step, the o-ring side of the
hydraulic fitting (68) faces the system. See F
e.
Install the supplied hydraulic fitting (68) with an
o-ring into the open port and tighten with an
11/16 in. wrench or socket.
f.
Install hose onto hydraulic fitting (68) with male
electrical connector side toward the system.
Use 11/16 in. wrench to tighten hose onto
hydraulic fitting (68).
g.
Locate MZLP (AA) connector marked with same
number as the hose fluid outlet port. Remove
that connector cover then install connector from
heated hose. See F
h.
Repeat the procedure for the remaining chan-
nels. Use the bottom melter ports first to ease
installation.
i.
Install cap on any unused MZLP electrical con-
nectors.
NOTE:
Fluid outlet port 1 must be used and electrical
connector from that hose must be connected to MZLP
connector 1. The system will not operate unless a hose
is connected to MZLP connector 1. If a hose is not con-
nected to connector 1, “Invalid Sensor - hose/gun” faults
will result. If the melter must be run without a hose/appli-
cator electrically attached to MZLP connector, use
Overtemperature Jumper, 16Y727
, page 113.
15. Install applicator(s), see F
NOTE:
Use of a Graco applicator is not required with
this system. However, all applicators attached to the
system must be rated for 1200 psi (8.3 MPa, 83 bar),
400°F (204°C), have an RTD type sensor, and use no
more than 400W at 240 VAC.
a.
Connect heated hose fluid outlet to applicator
fluid inlet. Use 11/16 in. wrench to tighten. See
. 11.
b.
For Graco applicators,
attach applicator electri-
cal connector to heated hose electrical connec-
tor. See F
c.
For non-Graco applicators,
attach applicator
electrical connector to adapter harness 16T916,
16T917, or 16Y828 then attach adapter harness
connector to heated hose connector. See
Non-Graco Applicator Adapter Cables
on
page 101 to determine which adapter cable to
use with your applicator.
To reduce the risk of fire and explosion, only use
Graco heated hoses with the InvisiPac system. Use of
non-Graco hoses will void agency approvals.
F
IG
. 11
ti23298a
W2
N
247
68
AA
Applicator
W1