GBESS 2.4_4.8KWH system user manual
28
BAT
Voltage
Current
AC
GRID voltage(on-grid)
GRID voltage(on-grid)
EMERGENCY LOAD voltage(off-grid)
EMERGENCY LOAD current(off-grid)
TEM
SolDate3100/3700TLtemperature
BM024temperature
FRE
Grid frequency
ET1
Daily PV production
SOC
Battery capacity
SWC
software version No. of SolDate3100/3700TLcommunication conversion board
SWM
CPU software version No. of SolDate3100/3700TL Master
SWS
CPU software version No. of SolDate3100/3700TL Slave
SWB
CPU software version No. of BM024
Table 12 LCD display Menu Content
4.1.5 LCD Setting Menu
Setting the device when initial commissioning.
Item
Description
PW
Password 1111 or 6666
TIM
Time
TYP
Battery type
00
Lithium-ion battery(default)
01
Lead battery
BVH
Battery charging stop voltage (default 54V)
BVL
Battery discharging stop voltage(lithium default 46V, lead-acid default 47V)
Id
Max discharging current(default 50A)
Ic
Max charging current(default 50A)
CER
Certification
00
G83(default)
01
VDE 0126/4105
02
AS4777
CNY
PV connection
01
Only PV1
02
Only PV2
03
PV independent (default)
04
PV parallel
MDE
Operation
mode
00
PV self of use(default)
01
Forced Time of Use(TOU)
00charging time
01discharging time
02
Back up reserved
04
Slave mode
ME1
Grid Meter address(001-255)
ME2
PV Meter address(001-255)
CT1
Current transformer for Grid Meter (1-99, default 01)
CT2
Current transformer PV Meter (01-99, default 01)
BMS
00
Pylon
Communication mode: RS485