Global Power Technologies
2-3
5120
2 .3 Data Plate
The data plate is located on the inside of the TEG cabinet door and indicates the following:
Fuel Type:
An X is stamped in the appropriate box for Natural gas or Propane. Each fuel type
requires a different orifice, therefore the TEG must be used with the fuel indicated.
Model Number:
The model number is interpreted as follows:
Serial Number:
Unique to each TEG.
Power, Fuel Pressure, Voltage:
These were measured during the factory performance test
and are for reference only. The operating power, fuel pressure and voltage are determined and
adjusted as per Section 2.6.
2 .4 Fuel Supply
Fuel Considerations
Clean Fuel:
The fuel used to operate the 5120 TEG must be clean (see gas specifications in
Appendix, page 7-3). If dirty fuel is anticipated then a customer supplied, in-line fuel filter is
recommended.
Low Temperature:
When using propane (C
3
H
8
) at
temperatures below -30ºC (-22ºF) special consideration
must be given to the low vapour pressure of the fuel.
Pressure:
Make sure that fuel pressure is at least 69
kPa (10 psig) and will not exceed 172 kPa (25 psig).
If it is expected that the fuel supply pressure will vary
greatly, the use of an additional primary regulator is rec
-
ommended. This will hold the input pressure relatively
constant.
Check the TEG data plate for the fuel type. DO NOT
use a different type of fuel than indicated.
DO NOT APPLY SEALANT ON
THE FIRST TWO THREADS
APPLY THREAD SEALANT
OVER THIS AREA
07193 rev1
Figure 3
Applying Thread Sealant
Fuel Type:
L = Propane
N = Natural Gas
Limiter Converter Voltage:
12 or 24 Volts
Fuel System:
SI
= Spark Ignition Only
SI-SO
= Spark Ignition & Auto Shut Off
5120 - ( ) - ( ) ( )
Summary of Contents for 5060
Page 2: ......
Page 4: ......
Page 6: ... ...
Page 8: ......
Page 10: ...Global Power Technologies 1 2 5120 ...
Page 15: ...Global Power Technologies 1 7 5120 ...
Page 27: ...Global Power Technologies 2 12 5120 Figure 13 Wiring Diagram 5120 TEG ...
Page 35: ...Global Power Technologies 3 8 5120 Figure 18 Burner Assembly ...
Page 47: ...Global Power Technologies 3 20 5120 ...
Page 50: ...Global Power Technologies 4 3 5120 Figure 26 220 Watt L C Connection and Adjustment Details ...
Page 51: ...Global Power Technologies 4 4 5120 ...
Page 55: ...Global Power Technologies 5 4 5120 Figure 30 Cathodic Protection System Parts Identification ...
Page 57: ...Global Power Technologies 5 6 5120 ...
Page 63: ...Global Power Technologies 6 6 5120 Figure 33 Exhaust Stack Removal ...
Page 75: ...Global Power Technologies 7 2 5120 7 2 Physical Dimensions Figure 42 Physical Description ...