2-2
5120
Mount the TEG to a firm and stable base, using 1/4-20 bolts, See Appendix Figure 42, page
7-2, for mounting hole locations. The base must be level and sturdy enough to support the
41 kg (90 lb) TEG. The TEG should be mounted high enough to avoid direct flooding or heavy
snowfall interfering with the flow of cooling air. Allow a minimum of 150 mm (6 in.) clearance
under the cooling fins.
WARNING: Operation of the TEG in locations where cooling air flow may be
obstructed will cause overheating of the TEG .
Figure 2
Assembling TEG