Global Power Technologies
1-3
5120
1 .1 .1 Health and Safety
Correct operation and maintenance according to this manual is critical for proper equipment
function and safety. Keep the following in mind when using these instructions.
1 .1 .2 Warnings
Throughout this manual you will notice paragraphs preceded by the text Warning. It is impera
-
tive that the advice in these paragraphs be adhered to as failure to do so may result in personal
injury or death and possible damage to the equipment and/or property. Warnings will be printed
in bold text in italics with the title WARNING in capital letters.
1 .1 .3 Cautions
Throughout this manual you will notice paragraphs preceded by the text Caution. It is impera
-
tive that the advice in these paragraphs be adhered to as failure to do so may result in damage
to the equipment. Cautions will be printed in bold text in italics with the title Caution.
1 .1 .4 Notes
Throughout this manual you will notice paragraphs preceded by the text Note. These para
-
graphs provide additional information or reference other sections of the manual, which may be
useful. Notes will be printed in italics .
1 .2 Standard Features and Options
1 .2 .1 Standard Features
The TEG comes standard with a fuel pressure regulator capable of accepting up to 172 kPa
(25 psi) and a built in fuel filter, an Automatic Spark Ignition System (SI), and low voltage alarm
contacts (Voltage Sensing Relay or VSR)
1 .2 .2 Options
Available options for the 5120 Thermoelectric Generator are as follows:
Automatic Shut-Off Option (SO):
The Automatic Gas Shut-Off option (SO) is designed to turn
off the gas supply to the burner if the flame in the TEG is extinguished and cannot be subse
-
quently re-ignited by the automatic SI system within approximately three to five minutes.
Corrosive Environment Fuel System Option (SS):
The Corrosive Environment Fuel System
is specially constructed with increased corrosion resistant components. All of the standard
brass fittings and gauge internals are replaced with stainless steel equivalents where possible
and the fuel regulator is upgraded to comply with NACE standard MR-01-75 (Sulphide Stress
Cracking Resistant Material For Oilfield Equipment). External components that can not be
replaced are coated with Glyptal to reduce their risk of corrosion.
Summary of Contents for 5060
Page 2: ......
Page 4: ......
Page 6: ... ...
Page 8: ......
Page 10: ...Global Power Technologies 1 2 5120 ...
Page 15: ...Global Power Technologies 1 7 5120 ...
Page 27: ...Global Power Technologies 2 12 5120 Figure 13 Wiring Diagram 5120 TEG ...
Page 35: ...Global Power Technologies 3 8 5120 Figure 18 Burner Assembly ...
Page 47: ...Global Power Technologies 3 20 5120 ...
Page 50: ...Global Power Technologies 4 3 5120 Figure 26 220 Watt L C Connection and Adjustment Details ...
Page 51: ...Global Power Technologies 4 4 5120 ...
Page 55: ...Global Power Technologies 5 4 5120 Figure 30 Cathodic Protection System Parts Identification ...
Page 57: ...Global Power Technologies 5 6 5120 ...
Page 63: ...Global Power Technologies 6 6 5120 Figure 33 Exhaust Stack Removal ...
Page 75: ...Global Power Technologies 7 2 5120 7 2 Physical Dimensions Figure 42 Physical Description ...