Global Power Technologies
1-1
5120
1 Introduction
This manual provides installation, operation and maintenance instructions for the
Global Power
Technologies Model 5120 Thermoelectric generators.
1.1 General Description and Specifications
The Model 5120 Thermoelectric Generator contains no moving parts. It is a reliable, low main
-
tenance source of DC electrical power for any application where regular utilities are unavailable
or unreliable.
Power Specifications
Power Ratings
20ºC, 750 m above sea level
120 Watts @ 6.7 Volts
108 Watts @ 12 Volts
108 Watts @ 24 Volts
108 Watts @ 48 Volts
Electrical
Adjustment
6.7 V
Up to 11 Volts
12 V 12-18 Volts
24 V
24-30 Volts
48 V
48-60 Volts
Reverse Current Protection
Yes
Output
Terminal block which accepts up to 8 AWG wire.
Opening for 3/4 in. conduit in the base of the cabi
-
net
Fuel
Natural Gas
8.8 m
3
/day (311 ft
3
/day) of Std. 1000 BTU/SCF
(37.7MJ/Sm
3
) gas
Propane
11.4 l/day (3.0 US gal/day)
Maximum Supply Pressure
172 kPa (25 psi)
Minimum Supply Pressure
69 kPa (10 psi)
Fuel Connection
1/4 in. MNPT connection
Environmental
Ambient Operating Temperature
Max. 45ºC (115ºF)
Min. -40ºC (-40ºF)
Operating Conditions
Unsheltered Operation
Materials of Construction
Cabinet
304 SS
Cooling Type
Natural Convection
Thermopile
Hermetically Sealed Lead Tin-Telluride (PbSnTe)
Fuel System
Brass, Aluminum & SS
Summary of Contents for 5060
Page 2: ......
Page 4: ......
Page 6: ... ...
Page 8: ......
Page 10: ...Global Power Technologies 1 2 5120 ...
Page 15: ...Global Power Technologies 1 7 5120 ...
Page 27: ...Global Power Technologies 2 12 5120 Figure 13 Wiring Diagram 5120 TEG ...
Page 35: ...Global Power Technologies 3 8 5120 Figure 18 Burner Assembly ...
Page 47: ...Global Power Technologies 3 20 5120 ...
Page 50: ...Global Power Technologies 4 3 5120 Figure 26 220 Watt L C Connection and Adjustment Details ...
Page 51: ...Global Power Technologies 4 4 5120 ...
Page 55: ...Global Power Technologies 5 4 5120 Figure 30 Cathodic Protection System Parts Identification ...
Page 57: ...Global Power Technologies 5 6 5120 ...
Page 63: ...Global Power Technologies 6 6 5120 Figure 33 Exhaust Stack Removal ...
Page 75: ...Global Power Technologies 7 2 5120 7 2 Physical Dimensions Figure 42 Physical Description ...