PART TWO - INSTALLATION
SECTION 2 - MECHANICAL REQUIREMENTS
PRO-series Model E3 Electrodeless Conductivity Transmitter
19
2.3 Panel Mounting
☞
Figure 2-2 illustrates how to panel mount the transmitter
using the supplied GLI panel mount hardware kit.
1.
Cut a 3.30-inch (84 mm) square cutout hole in panel.
2.
Position panel-mount gasket over cutout in front of
panel, and place retainer plate behind panel with its
four threaded inserts facing away from back of panel.
3.
Attach transmitter to retainer plate using its four captive
screws.
NOTE:
If panel is too thick, remove captive screws
from transmitter, and use longer screws pro-
vided in hardware kit.
FIGURE 2-2 Panel Mounting Details