Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
8
Distance Mode Screen
In Distance mode, the feed rate is automatically set by dispensing feed over a set distance.
Screen Features:
The top line shows the weight to feed out.
The second line shows the distance over which to feed this weight.
The third line shows the present wagon weight. This may be gross or tare.
The bottom line of the screen shows the status of the system (STOP), the mode of operation (Dist), the
battery voltage (highest voltage available to the unit. When disconnected from the tractor, this will be the
internal battery voltage), and connectivity status.
Operating Notes:
Screen Warnings:
“WAGON POWER NOT CONNECTED” will flash on the display if the GO button on the Remote Display is
pressed without the wagon being plugged into the tractor and/or power not getting from the tractor to the
Controller.
“INCREASE GROUND SPEED” will flash on the display when the wagon is travelling too slow and causing
the machine to overfeed. Note that ground speed needs to increase not tractor revs.
“DECREASE GROUND SPEED” will flash on the display when the wagon is travelling faster than the
machine can feed. Note that ground speed needs to decrease not tractor revs.
TO FEED:
1800kg
LENGTH:
100m
GROSS:
2950kg
STOP Dist 12.5V
Mode of operation
System status
Feed to dispense
Distance to travel
Product weight in machine
Connectivity status
Battery voltage
System battery indicator
The operator can adjust the weight to be dispensed by adjusting the
‘TO FEED’ figure. This is done by pressing UP or DOWN on the
keypad when the ‘TO FEED’ figure is underlined. Use the RIGHT or
LEFT button to move the underline cursor.
The operator can adjust the distance to feed the weight over by
adjusting the ‘LENGTH’ figure. This is done by pressing UP or DOWN
on the keypad when the ‘LENGTH’ figure is underlined. Use the
RIGHT or LEFT button to move the underline cursor.
The operator can start or stop the operation by pressing GO or STOP
on the keypad. If the feed bins are unequal in length, enter the total
length of the bins in the ‘LENGTH’ figure and the total amount to feed
in t
he ‘TO FEED’ figure. After travelling the first bin, press STOP on the
keypad. The display will change from RUN to WAIT. You can then
travel forward or backward without the distance changing. Press GO to
continue or press and hold the STOP button for 3 or more seconds to
reset the system status to STOP. The system will automatically return
to STOP mode after counting down the distance to zero.
The operator can switch to other available operating modes by
pressing MODE on the keypad.
The operator can select between gross and tare weight to be displayed
by pressing TARE/GROSS on the keypad.
The operator can zero the gross and dispensed weight by pressing
ZERO on the keypad.