Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
19
*** SETUP ***
Low Batt Level
11.50V
RANGE: 0-30
*** SETUP ***
Valve Fitted
YES
RANGE: 0-1
*** SETUP ***
Min Valve Setting
30.00
RANGE: 0-100
*** SETUP ***
Valve Ramp Up Time
0.00sec
RANGE: 0-10
*** SETUP ***
Valve Startup Dist.
85.00%
RANGE: 0-100
*** SETUP ***
Valve Ramp Up Time
0.00sec
RANGE: 0-10
Low Battery Level
The "Low Batt Level" parameter defines the minimum
battery voltage level at which the screen will switch
from displaying voltage to displaying “LOBAT”. This
function can be cancelled by setting the voltage to
0.00V.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Solenoid Valve Fitted
The
‘Valve Fitted’ parameter indicates if the solenoid
valve is fitted or not and displays appropriate modes to
suit.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Minimum Valve Setting
The "Min Valve Setting" parameter defines the
minimum valve opening percentage when in Distance
and Speed mode, while running. When stopped, the
valve will go to 0.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Valve Ramp Up Time
The ‘Valve Ramp Up Time’ parameter changes the
valve ramp up time.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Valve Ramp Down Time
The ‘Valve Ramp Down Time’ parameter changes the
valve ramp down time.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Valve Start-up for Distance Setting
The “Valve Startup Dist.” parameter is the initial valve
setting to use when the machine is started in Distance
mode.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.