Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
18
*** SETUP ***
Scale Hysteresis
10.00kg
RANGE: 1-200
*** SETUP ***
Scale Increments
10.00kg
RANGE: 1-200
*** SETUP ***
Wheel Diameter
760.00mm
RANGE: 0-1400
*** SETUP ***
No. of Wheel Holes
15.00
RANGE: 0-50
*** SETUP ***
Max Valve PSI
2100.00psi
RANGE: 0-3000
*** SETUP ***
Wheel Sensor Fitted
YES
RANGE: 0-1
Scale Hysteresis
The “Scale Hysteresis” parameter specifies how much
a weight reading needs to change before the reading
on the screen will change.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Scale Increments
The
“Scale Increments” parameter specifies minimum
scale increment displayed on the screen.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Maximum Valve Pressure
The ‘Max Valve PSI’ parameter sets the elevator load
sensing pressure. Reduce this value if the elevator
stalls too often. Ideally this should be set
approximately 200
– 300 PSI below tractor relief
pressure.
The operator can press UP or DOWN to adjust this value. Press MODE to continue.
Wheel Sensor Fitted
The ‘Wheel Sensor Fitted’ parameter indicates if the
wheel sensor is fitted or not and displays appropriate
modes to suit.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Wheel Diameter
The “Wheel Diameter” parameter is used to calibrate
the wheel size on the machine.
The operator can press UP or DOWN to adjust this
value. Note: For accuracy, measure from the ground to
the centre of the hub (and double) when the machine is
half loaded. This will compensate for tyre pressure.
Press MODE to continue.
Number of Wheel Holes
The “Number of Wheel Holes” parameter is used to
calibrate the distance measurement for the number of
holes on the encoder disk used by the speed sensor.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.