Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
6
Standard Mode Screen
In standard mode, the feed rate is shown as a percentage. A range of 1-100% is available
with 100% being maximum feed rate. This rate is shown on the top line of the screen. This
mode is useful for general operation and is the most simple to use.
Screen Features:
The top line shows the feed rate.
The bottom line of the screen shows the status of the system (STOP), the mode of operation (Std)
and connectivity status.
Additional features that show if load cells are fitted:
The second line will show the weight dispensed since GO was pressed.
The third line will display the present wagon weight. This may be gross or tare.
The bottom line of the screen shows the status of the system (STOP), the mode of operation
(Std), the battery voltage (highest voltage available to the unit. When disconnected from the
tractor, this will be the internal battery voltage), and connectivity status.
Operating Notes:
Screen Warnings:
“WAGON POWER NOT CONNECTED” will flash on the display if the GO button on the Remote
Display is pressed without the wagon being plugged into the tractor and/or power not getting from
the tractor to the Controller.
FEED RATE:
50%
DISPENSED:
1050kg
GROSS:
2950kg
STOP Std 12.5V
FEED RATE:
50%
STOP Std
Rate control only
Rate control with
load cells fitted
Feed Rate
System status
Mode of operation
Connectivity status
Dispensed amount
Product amount in machine
Battery voltage
System battery indicator
The operator can adjust the rate percentage figure by pressing UP or
DOWN on the keypad.
The operator can select between gross and tare weight to be
displayed by pressing TARE/GROSS on the keypad.
The operator can zero only the dispensed weight by pressing GO on
the keypad.
The operator can start and stop the feed-out by pressing GO and
STOP on the keypad.
The operator can switch to other available operating modes by
pressing MODE on the keypad.
The operator can zero the gross and dispensed weight by pressing
ZERO on the keypad.