Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
17
*** SETUP ***
Scale Damping Value
1.00
RANGE: 1-15
*** SETUP ***
Load Cell Type
5000.00kg
RANGE: 5000-10000
*** SETUP ***
Number of Load
Cells
4.00
RANGE: 0-6
*** SETUP ***
Load Cell Sens.
2.00mV/V
RANGE: 0-10
Setting System Parameters
Parameters are required to be set for the machine to function correctly.
Entering Configuration Screens
To enter set-up, press TARE/GROSS and ZERO together for 4 seconds or until the
set-up screen appears.
Press UP or DOWN to adjust the parameter.
Press MODE to move to the next configuration screen. It will save what is displayed
on the screen.
Press STOP to exit the configuration screens.
Scale Damping Value
The
“Scale Damping Value” parameter is a weighting
value over which the weight is averaged. A higher
value will display a smoother weight display but won’t
react to weight changes as quickly.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Load Cell Type
The
“Load Cell Type” parameter specifies the
maximum load for each individual load cell used on the
wagon.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Number of Load Cells
The
“Number of Load Cells” parameter specifies the
total amount of load cells fitted to the machine. Enter 0
if no load cells are fitted.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.
Load Cell Sensitivity
The
“Load Cell Sens.” parameter specifies sensitivity of
the load cells used on the wagon. The setting is in mV
per Volt. This means mV output per Volt of excitation.
This is a characteristic of the load cells used.
The operator can press UP or DOWN to adjust this
value. Press MODE to continue.