Remote Display Mounting & Power Supply
The Remote Display is designed to be mounted in the tractor cab and be easily accessible to
the driver. It contains a radio frequency (RF) communication device to control the Forage
Wagon Controller (Controller).
It will require shielding from the weather elements of sun and rain etc.
The Remote Display requires 12-24 volts DC to operate. It will typically only draw 0.2A. The
power supply must originate from the tractor battery as part of the installation loom (supplied
with the machine).
Forage Wagon Controller & Power Supply
The Forage Wagon Controller is powered from the tractor while operating. When
disconnected from the tractor, it draws power from its own sealed lead acid battery.
No installation wiring is required on the Forage Wagon.
The tractor requires an installation loom (supplied) which provides a switched and fused
positive and negative supply from the tractor battery to the rear 7-pin socket. The tractor
battery is the best power supply point as it provides the most stable and “quiet” power
source. Do not use any other power source.
Tractor Plug
There are three CPC connectors on the Controller module.
If a connector is not used, place the terminal cap over it.
RF positive supply from
wiring loom (BROWN)
RF negative supply from
wiring loom (BLUE)
Terminal cap
Wagon plug:
RF positive supply
(BLACK) wire to be in
pin 2
RF negative supply
(BLUE) wire to be
combined with (WHITE)
wire into pin 3