Generation II RF Control System – Operating, Installation & Technical Manual
RF Gen II System Technical Manual Rev02_12_10
4
IMPORTANT
Manual over-ride located beneath this
cover
To operate in case of electronic
malfunction, undo locking ring and
screw in adjuster.
Use ¼ - ½ turn adjustments.
Operation Section
Overview
Assuming installation (page 11
– 23) has been completed, the power for the system is
controlled by the switch adjacent to the Remote Display.
1. Turn the switch on to provide power to the Remote Display and the wagon.
2. If the wagon is disconnected, press and hold the ON button on the Controller for one
second. The Controller is now operating on its own battery.
3. Begin loading the wagon. See more detailed information regarding modes and
buttons.
4. Once completed loading, connect the wagon to the tractor and connect the 7-pin
plug.
5. Once ready to feed, select the appropriate mode and press GO button. You are now
ready to proceed.
Note: The Controller power light will illuminate when the ON button is pressed or the wagon
is plugged into the tractor. To turn off, the wagon must be un-plugged before pressing the
OFF button.
Valve Over-ride Function
When a solenoid is fitted for floor control, a manual over-ride function will also be provided.
Note: This function over-rides all RF floor rate control
.
Use ¼ - ½ turn adjustments per time. Do not over-adjust.
For electronic operation with RF control, the screw adjuster must be unscrewed all the way
out (anti-clockwise) and the locking ring tightened.
Locking ring
Over-ride adjuster
Label on cover