Gill Instruments Ltd
_____________________________________________________________________________________________________________
________________________________________________________________________________________________
MetPak/MetPak RG and MetPak Pro Base Stations
Page | 100
Issue 1
Doc. No. 1723-PS-0023
October 2018
8.3.2.
MetPak Base Station Range Sensor Status Codes
Code
Status
Condition
00
OK
No fault conditions detected in
measurement period.
A
Acceptable Data (NMEA Mode)
No fault conditions detected in
measurement period.
01
Wind Sensor Axis 1 failed
U Axis blocked or faulty.
02
Wind Sensor Axis 2 failed
V Axis blocked or faulty.
04
Wind Sensor Axis 1 and 2 failed
U and V axis blocked or faulty.
08
Wind Sensor NVM error
Non Volatile Memory checksum failed,
data could be uncalibrated.
09
Wind Sensor ROM error
Read Only Memory checksum failed, data
could be uncalibrated.
0B
Wind Sensor reading failed.
Wind Sensor faulty.
10
Hygroclip error
Hygroclip faulty.
20
Dewpoint error
Hub Pec faulty.
40
Humidity error
Hygroclip faulty.
66
Wind Sensor Power
Check Wind Sensor is powered
67
Wind Sensor RS232
Communications
Check Wind Sensor RS232 wiring
80
Pressure Sensor Warning
Pressure sensor reading not available/unit
faulty.
XX
More than one fault
Fault condition that can be the sum of
0B,10, 20 or 40. e.g. 1B would mean that
both the Wind Sensor (0B) and Hygroclip
(10) were faulty.
V
Void Data, Wind Sensor reading
failed (NMEA mode)
Wind Sensor faulty.