34
Pre-Operation
GBF Ventless Electric Fryer
GBF-35D & 50D-VH
1. Follow steps shown in
Section 4.01
.
2. Open Cabinet Door.
If not done previously, disconnect and remove Filter Pan
from the unit
.
3. Firmly press the palm of the hand over the Filter Pan Quick-Disconnect
①
fitting
on the Fryer.
4. While covering the opening with the hand, set the Pump Switch
②
to the
[PUMP]
position. The pump should start ... if suction is felt on your hand, it is operating
correctly. Return switch to
[OFF]
...
ONLY allow pump to run long enough to check
for suction
. Proceed to
Section 4.05
.
If the pump does not start or suction is not detected, refer to
Section 7.02,
Troubleshooting Procedures
.
The following test is to confirm that the Filter Pump is operating correctly.
1
2
4.04
Filter Pump Test