17
Overview
GBF Ventless Electric Fryer
GBF-35D & 50D-VH
3.02.1 Control Panel - Computer Controller
Item
Description
Function
1
Power Switch
Main Power Switch ... turns Fryer power
ON
or
OFF.
2
Selector Switch
Selector Switch ... 3-position switch to select operation mode ...
[COOK-OFF-PUMP]
. Heating elements only operate when in the
[COOK]
position. The switch is placed in the
[PUMP]
position to run
the Filter Pump. Centered position is
[OFF]
.
3
Computer Controller
Computer Cooking Controller ... set cooking temperature and cook
times ... controls and monitors fryer functions ... displays alarm
conditions and operational prompts. Stores fifty (50) programmable
Menu Item preset cooking times. Features 2 displays ... upper
OLED
Display
shows errors, alarms, operational prompts & instructions;
lower
7-Segment Display
shows cooking values for temp, time, User
settings, etc).
3.1
Function Keys
Keys activate various Controller functions.
3.2
Controller Keypad
Enter menu numbers, time & temp values, start & cancel features,
etc. Keys
[2], [4], [6] & [8]
act as arrow keys for various functions.
5
Power Indicator Light (Green) Light is illuminated whenever the main Power Switch is in the
[ON]
position.
6
Heat Indicator Light (Amber)
Light is illuminated when the Heat Switch is in the
[HEAT]
position
and the heating elements are energized. This light will cycle
ON
and
OFF
during normal operation as the Controller maintains the set-
point temperature.
7
High-Limit Indicator (Red)
Light is illuminated to indicate shutdown of the heating elements
due to excessive heat condition. Should this light turn on during
operation,
DISCONTINUE COOKING ACTIVITIES
and refer to
Troubleshooting, Section 7
.
DO NOT ATTEMPT TO CONTINUE
COOKING UNTIL THE CAUSE OF THIS CONDITION IS DETERMINED!
8
EAC Status [ON]
The
ON
Indicator Light is on when the Electronic Air Cleaner (EAC)
power supply is on and operating normally.
9
EAC Status [WASH/CHECK]
The
WASH & CHECK
Indicator Lights illuminate to indicate an alarm
condition with the EAC system. The EAC Cell is excessively dirty,
shorted out, poor contact, faulty component, etc. Power to
heating elements will be shutdown approx. 2 minutes after these
lights turn
ON
.
DO NOT
use these lights as a signal for routine
cleaning ... the Cell must be cleaned
DAILY
to maintain peak
performance.
10
Fire Extinguisher Manual Pull
Handle
In case of an accidental cooking vat fire, pulling this handle will
manually actuate the fire suppression system. Fire system also will
actuate automatically.
Summary of Contents for GBF Series
Page 2: ......
Page 4: ......
Page 12: ...x Safety GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 16: ...4 Introduction GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 32: ...20 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 5 6 2 4 1 3 7 3 03 Lower Cabinet ...
Page 36: ...24 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 2 1 3 7 4 5 6 8 3 05 Ventless Hood ...
Page 48: ...36 Pre Operation GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 110: ...98 Troubleshooting GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 128: ...116 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 129: ......