51
Fryer Operation
GBF Ventless Electric Fryer
GBF-35D & 50D-VH
5.01.7.2 AUTO-COOL Feature
5.01.7.3 BOIL OUT Mode
IMPORTANT!
Fryer must be properly drained, rinsed and prepared for cooking after a Boil Out cycle. See
Section
6, Cleaning
.
Pressing the
[BOIL]
key while Controller is in
PREHEAT
state enters
BOIL OUT Mode
.
Temperature and time change to the
BOIL TEMP
and
BOIL OUT TIME
, respectively, as
specified in
USER SETTINGS (see
Section 5.01.8
)
.
Factory-default is BOIL TEMP = 200°F ...
BOIL OUT TIME = 30 minutes
. These settings can be edited by User within the ranges of
BOIL TEMP = 185° to 208°F
and
BOIL OUT TIME = 1 to 45 minutes
.
Exit AUTO-COOL
same as
COOL ...
press the
[CLEAR]
key, then press
[<4]
to exit
COOL - OR -
press
[CLEAR]
again to continue
COOL
Mode.
Upon exit, the temperature setpoint will return to the previous active value and
Fryer will enter
PREHEAT
mode until temperature is reached.
+
When the
AUTO-COOL
feature is turned
[ON]
, the Fryer automatically enters
COOL Mode
after no cook cycles are
started within the amount of time specified by the
AUTOCOOL TIME
setting in
USER SETTINGS, s
ee
Section 5-01.8,
Edit User Settings
.
Factory-default = [OFF] ... AUTOCOOL TIME = 30.
Setting can be enabled/edited by User in the
range of
1 to 510 mins.
Summary of Contents for GBF Series
Page 2: ......
Page 4: ......
Page 12: ...x Safety GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 16: ...4 Introduction GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 32: ...20 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 5 6 2 4 1 3 7 3 03 Lower Cabinet ...
Page 36: ...24 Overview GBF Ventless Electric Fryer GBF 35D 50D VH 2 1 3 7 4 5 6 8 3 05 Ventless Hood ...
Page 48: ...36 Pre Operation GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 110: ...98 Troubleshooting GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 128: ...116 Parts List GBF Ventless Electric Fryer GBF 35D 50D VH ...
Page 129: ......