Table 9: Component Temperature Thresholds and Actions
Transceiver
Temperature
Exhaust
Temperature
CPU
Temperature
Switch CPU
Temperature
75ºC
Warning trap sent
70ºC
Warning trap sent
95ºC
Warning trap sent
100ºC
Warning trap sent
80ºC
Alert trap sent;
Transceiver power
disabled
75ºC
Alert trap sent
100ºC
Alert trap sent
105ºC
Alert trap sent; Switch
CPU put in reset
85ºC
Critical trap sent
80ºC
Critical trap sent
105ºC
Critical trap sent
110ºC
Critical trap sent
The output of the following CLI command displays the current exhaust, CPU, and switch
CPU temperatures, as well as the intake temperature:
(config) show environment
...
Card 1 (TA200-C64):
Intake temperature :
29 C
Exhaust temperature :
28 C
CPU temperature :
36 C
Switch CPU temperature :
54 C
The output of the following CLI command displays the transceiver temperature:
(config) show port params port-list 3/1/c1
Parameter
3/1/c1
======================
===============
...
SFP type:
qsfp28 sr
...
SFP Power (1-2) (dBm):
-40.00 -40.00
SFP Power (3-4) (dBm):
-40.00 -40.00
SFP Power (5-6) (dBm):
-
-
SFP Power (7-8) (dBm):
-
-
SFP Power (9-10)(dBm):
-
-
SFP Temperature (C):
19.75
...
The output of the following CLI command displays the fan speed in RPM (the normal
operational speed is approximately 5000
RPM; the maximum speed is approximately
12500
RPM):
(config) show environment
...
-----------------------------------------------------------
Fan tray 1 (FAN-TAC20):
1st fan :
12136 RPM
2nd fan :
12522 RPM
Contents
44