GigaVUE TA Series-TA40 equipment or subassembly are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the
equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the OSP or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 6) and
require isolation from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP wiring.
Intrabuilding or Intra-connection for GigaVUE TA
Series-TA100
WARNING: The intra-building ports:
• RJ45: Management port, Console port
• 100G QSFP28: C1-C32
• 40G QSFP+: C1-C32
GigaVUE TA Series-TA100 equipment or subassembly are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the
equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the OSP or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 6) and
require isolation from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP wiring.
Intrabuilding or Intra-connection for GigaVUE TA
Series-TA200
WARNING: The intra-building ports:
• RJ45: Management port, Console port
• 100G QSFP28: C1-C64
• 40G QSFP+: C1-C64
GigaVUE TA Series-TA200 equipment or subassembly are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The intra-building port(s) of the
equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the OSP or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 6) and
require isolation from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP wiring.