UFO-NT
6
Abbreviations
1.5 Disposal of the door system
à
The door system is made up of materials that should be sent for recycling.
The individual components have to be sorted in accordance with their material type.
à
Aluminium (profiles, cover, return pulleys, sliding blocks, ...)
à
Iron (drivers, screws, ...)
à
Plastic
à
Electronic components (dead bolt, motor, control, transformer, sensors, ...
à
Cables
The parts can be disposed of at the local recycling depot or by a scrap recycling company.
à
Batteries contain pollutants and heavy metals. Do not dispose of with household waste.
Turn over rechargeable batteries to your local recycler.
2
Abbreviations
Wire colours
BN brown
BK black
BU blue
GN green
GY grey
YE yellow
OG orange
PK pink
RD red
TQ turquoise
VT violet
WH white
Connections, terminals and plugs
AU Automatic
BS
Hinge side
BGS
Opposite hinge
side
DO
Hold open
DPS DPS
END
Latching action
GF
Active leaf
GND
Reference poten-
tial
KA
Contact sensor
outside
KB
Mechanical con-
tact
KI
Contact sensor
inside
LK
Luster terminal
LS
Exit only
MPS
Mechanical programme
switch
NA Night
PA
Configurable output
PE
Configurable input
RBM
Radar movement detec-
tor
RES
Reset switch
RM
Bolt message
RSZ
Smoke control unit
RS485
Communication signal to
DPS and second drive
OFF
OFF mode of operation
SF
Passive leaf
STOP Stop
SCR Screen
SO
Opening safety sensor
SIS
Closing safety sensor
STG Fault
TK
Door transmission cable
TOE
Electric strike
TST
Test signal for safety sen-
sors
24V
Supply voltage for exter-
nal devices
24VSENS Supply voltage for sen-
sors, connected after
setting the ECO mode
3
Electrical data
Mains voltage
230 V AC –15 %, +10 %
Frequency
50 Hz
Protection rating
I
Capacity rating
200 W
Mains connection
Fixed connection (installation cable or cable connection)
Primary fuse
–
Secondary fuse
10 A slow-blow, 5×20 mm
Secondary voltage (transformer)
33 V AC (46 V DC)
Control voltage for external components
24 VDC ±10 %
Output current control voltage 24 V
1200 mA permanently 1800 mA briefly (5 s, duty ratio
30 %)
Fuse protection <24 V
2.5 A; reversible
Temperature range
–15 … +50 °C
IP rating
IP version IP67
F version IP62
Summary of Contents for UFO-NT F