UFO-NT
54
Service menu
27.3.5 Movement parameters
Name
1 Sub-menu
2 Sub-menu
Explanation
Speeds
Opening time
Value:
4
s
min
3
s
max.
25
s
Opening time
*)
with automatic
opening. Setting pursuant to
the table in the Powerturn
installation instructions.
Closing time
Value:
5
s
min
5
s
max.
25
s
Closing time
*)
as per automatic/
manual opening. Setting pursu-
ant to the table in the Power-
turn installation instructions.
Manual closing time
Value:
15
s
min
5
s
max.
25
s
Closing time after manual open-
ing or after automatic opening
with set automatic door closing
mode.
Setting pursuant to the table
in the Powerturn installation
instructions.
Latching action
Value:
0
min
0
max.
50
Sets the speed at which the
drive moves to the closed posi-
tion shortly before closing. This
is required e.g. for operation
with a motor lock. Latching
action also applies for manual
passage.
Move towards open
Off
In the event of further opening
attempts, the drive stops before
the obstacle in the opening
range
Obstacle motor On
Drive presses against obstacle in
the opening range.
Obstacle motor Off
Drive presses against obstacle in
the opening range and reduces
motor current to 0 A.
Free swing function
no
yes
For doors without external
loads, such as wind or pres-
sure, the parameter “free swing
function” can be activated in
order to enable forced closing
movement of the door.
*)
the values for opening time and closing time refer to an opening angle of 90°.
Braking force
Value:
13
Value
min
1
max.
14
Braking force during closing via
spring action following power
failure or fire alarm.
Forces
Opening force
Value:
150
N
min 10 N
max. 250 N
Open static force at the main
closing edge.
Closing force
Value:
150
N
min 10 N
max. 250 N
Close static force at the main
closing edge.
Obstacle
Value:
3
0.1 s
min 1 0.1 s
max 20 0.1 s
Time for which the drive pushes
against an obstacle with the set
static force.
Opening retention
force
Value:
00
N
min 00 N
max 70 N
Constant force on the main clos-
ing edge in open position.
Close retention force Value:
00
N
min 00 N
max 70 N
Constant force on the main clos-
ing edge in closed position.