UFO-NT
20
Contact sensor outside
8
Contact sensor outside
à
The KA input is only active in the AU mode of operation.
à
In the case of 2-leaf systems, the contact sensor outside can be connected to the active leaf control or to the
passive leaf control.
à
Upon activation, the active leaf opens and, if switched on, the passive leaf opens.
The state of the drive to which the ST220 is connected is displayed.
X
Press the
button.
X
Select "Active leaf para" or "Passive leaf para" using the
or
key and press the
key.
For further settings, see the descriptions below.
à
The sensor for monitoring closing can also be used as a contact sensor outside.
à
Set the parameters with:
à
DPS: Set
f1
to
0 4
.
à
ST220: Set the "Signals", "Input signals", "SI1 – terminal SIS1", "SI1 function" to "SIS and KA".
à
An activation delay time can be set for the KA input. This time is added to the general activation delay time
(opening delay).
Set the parameters with:
à
DPS: Set
aa
to the desired delay time (0 s ... 9 s).
à
ST220: Use the
or
key to set "Signals", "Input signals", "KA", "KA delay" to the desired delay time
(0 s … 9 s) and press the
key.
8.1 GC 302 R radar movement detector
à
For information see GC 302 R (KI).
à
Upon activation, the output of the GC 302 R is closed (24
V applied to the KA input).
à
Set the Contact type parameter with:
à
DPS: Set
cO
to
01
(default setting).
à
ST220: Set the "Signals", "Input signals", "KA" and
"KA contact type" to " NO contact " (default
setting).
WH
BU
BK
BN
50 mA
+UB
-UB
GC 302 R
1
2
3
4
5
24VSENS
KA
GND
4
23
1
KÂ
8.2 Push button (floating normally opened contact)
à
For information see push button (KI).
à
Set the Contact type parameter with:
à
DPS: Set
cO
to
01
(default setting).
à
ST220: Set the "Signals", "Input signals", "KA" and
"KA contact type" to " NO contact " (default
setting).
23 KA
1 GND
4 24VSENS
KA
Summary of Contents for UFO-NT F
Page 1: ......
Page 7: ...UFO NT 7 Supply terminals 4 Supply terminals DCU800 1 2 24V GND 6 1 RS485 passive leaf 2 FREE ...
Page 79: ...UFO NT 79 ...
Page 80: ......