UFO-NT
25
Configurable inputs
11.7.3 Switch function hold-open time
For 2-leaf drives, the settings on the active leaf control determine the hold-open time.
DPS
X
Set
e1
or
e2
to
11
for:
1 switch contact = open door / 2nd switch contact = close door
If the SIO is triggered before the hold-open time or the 2nd switch contact is activated, the hold-open time runs
out and is not cancelled by the 2nd switch contact.
At the latest after the end of the hold-open time
à
O h
for 2-leaf drive and 2-leaf mode of operation, if the button is connected to the passive leaf drive.
à
O ®
for 1-leaf drive or 2-leaf drive and the "reduced opening" mode of operation, if the push button is con-
nected to the active leaf drive.
ST220
Set "PE1", "PE1 function" or "PE2", "PE2 function" to "Push button hold-open time NO” for:
1 switch contact = open door / 2nd switch contact = close door
Door closes no later than upon expiration of the hold-open time.-
51 PE1
2 24V
PE1 GF
52 PE2
PE2 GF
oder
53 PE3
PE3 GF
oder
11.8 Control reset
à
The control can be reinitialised via the configurable inputs. After the push button has been activated, the
drive behaves as though the mains voltage has been switched on.
à
Set the parameters with:
à
DPS: Set
e1
,
e2
or
e3
to
1 3
(reset switch).
à
ST220: Set “PE1 function", "PE2 function" or "PE3 function" to "Reset switch NO".
51 PE1
2 24V
PE1 GF
52 PE2
PE2 GF
oder
53 PE3
PE3 GF
oder
11.9 Double push button (1-leaf / 2-leaf door opening)
In the case of 2-leaf drives, the door can be opened via the configurable door inputs of the active leaf control in
the 1-leaf or 2-leaf mode as desired by pressing a button if the "1-leaf opening" mode of operation is active. If the
push button is pressed once, only the active leaf opens and closes after the 1-leaf hold-open time has expired. If
two two buttons are pushed within 1.5 s, the active and passive leaves open and close after the end of the hold-
open time 2-leaf.
Set the parameters with:
à
DPS: Set
e1
,
e2
or
e3
to
1 4
(double push button).
à
ST220: Set "PE1 function", "PE2 function" or "PE3 function" to "Double push button".
51 PE1
2 24V
PE1 GF
52 PE2
PE2 GF
oder
53 PE3
PE3 GF
oder