UFO-NT
10
"Open" and "close" safety sensor
5.1.1 Monitoring closing and opening
Standard operation
X
Setting the "Contact type" parameter;
à
DPS: Set
s1
and
s3
to
0 2
("NC") (default set-
ting).
à
ST220: Set the "Input signals", "SI1 – terminal
SIS", "SI1 contact type" to "NC" and
"SI3 – terminal SIO", "SI3 contact type" to
"NC" (default setting).
Energy-saving mode
X
Setting the "Contact type" parameter;
à
DPS: Set
s1
and
s3
to
0 3
(frequency) (default
setting).
à
ST220: Set the "Input signals", "SI1 – terminal
SIS", "SI1 contact type" to "frequency" and
"SI3 – terminal SIO", "SI3 contact type" to
"frequency".
X
Setting the Function parameter:
à
DPS: Set
f1
to the desired function and
f3
to
0 5
(SIO stop) or
0 6
(SIO stop SF-GF).
à
ST220: Set the "Input signals", "SI1 – terminal
SIS", "SI1 function" to the desired
function and
"SI3 – terminal SIO", "SI3 function" to "SIO
stop" or "SIO stop SF GF".
S
E
GY
2
1
4
3
5
BN
BK
BU
WH
SIGNAL
24V
SIO
GND
SIS
100mA
S
1
13
10
4
SIO
SIO
GND
24VSENS
TST
1
11
10
4
SIS
SIS
GND
24VSENS
TST
E
oder
1
2
2
1
3
4
1
Opposite hinge side
2
Hinge side
3
Door transmission cable
4
GC 338 interface module