UFO-NT
16
"Open" and "close" safety sensor
5.3.4 GC 334 connection over interface GC 334
1
GND
13
SIO
10
TST
4
24VSENS
SIO
Interface
GC 334
4
3
2
5
1
11
SIS
SIS
GC 334
BS
-
+
-
+
GC 334 Module
BS
GC 334 Module
BGS
60mA
1
1
Door transmission cable
5.4 Safety sensor GC 335
à
GC 335 master module, mat. no. 128074
GC 335 extension kit (slave module with accessories), mat. no. 128072
à
Follow the installation instructions
à
Accessories:
à
GC 332 adapter, mat. no. 124035
à
Spot finder, mat. no. 112321
X
Use the reference body, mat. no. 120190, to set the detection field.
X
Always install the master module near the hinge, connection with the drive control takes place at the master
module.
X
Connect max. 7 slave modules to one master module.
X
Open the configuration bridge at the last slave module or at the master module (if no slave modules con-
nected).
X
Set the "Testing" parameter.
à
DPS: Set
Te
to
01
(testing with 24 V).
à
ST220: Set "Output signals", "Testing SI" to "Testing with 24 V".