UFO-NT
74
Service menu
DPS Parameter
Setting values
Explanation
12
Stop 12 kOhm
NO For the connection of a stop push button with 12 kOhm termi-
nating resistor
13
Reset switch
NO For restarting the drive. Function as reset.
14
Double push button NO Open 1× press = 1 leaf open
Open 2× press = 2 leaf open
15
Stop NO
NO For connection of a stop push button
16
Stop NC
NC
19
Closed position SF
closed position contact for the passive leaf for 2-leaf door with
manual passive leaf (door closer):
20
Stop 20 kOhm
NO For the connection of a stop push button with 20 kOhm termi-
nating resistor
21
WC control
Connection of the internal button
for the WC function.
22
Fire alarm
If active, the door opening torque function with fire alarm
torque is set for the duration.
23
1-leaf opening
In 2-leaf systems, when the signal is active on the active leaf only
1 leaf is opened.
a1
Configurable
output 1
00 Not used
a2
Configurable
output 2
01 Gong
If KA is triggered
02
Fault NO contact
The function is used for fault messages, e.g. to a customer build-
ing control centre. The contact closes or opens respectively if
the control determines a fault.
03
Fault NC
04
Fault MPS
The function is used to switch the fault LED at the MPS. The con-
tact closes if the control determines a fault. When maintenance
is due, the output is connected cyclically, and the fault LED on
the MPS flashes.
05
Warning signal
The function is used to cyclically switch on/off a signal transmit-
ter while the door is opening or closing.
06
Electric strike
For the connection of an additional electric strike
08
closed lock
The function is used to signal the door mode, e.g. to a building
control centre.
09 Closed
10
Not closed
11 Open
12 Off
13 Night
14
Exit only
15 Automatic
16
Hold open
17
Light control
The function is used to activate a light controlling device which,
for example, switches on the entry illumination as soon as a con-
tact sensor (KI, KA, KB, SIS+KI, SIS+KA) is activated or the door is
opened manually.
18
Day/Night changeover
The function is used to signal the day mode of operation to a
customer building control centre. The output switches to GND if
the mode of operation LS, AU 1-leaf, DO, or AU 2-leaf is set.
19
Not used
20
Maintenance due
The function is used to signal the door mode, e.g. to a building
control centre.
21
holding magnet GF
To set the active leaf holding magnet.
22
holding magnet SF
To set the passive leaf holding magnet.
24
WC timeout
To connect a lamp or a signal to signal when the 30-minute
timer has expired for the WC function.
f0
Opening force
01 …
15
… 25
×10 N;
Open static force at the main closing edge.
Summary of Contents for UFO-NT F