Power supply connections
Each indoor monitor requires its own power supply. Connect the GPE302-
type power pack’s
E1
plug to socket
C1
. Alternatively, use a central power
supply system (not supplied) and connect it to plug-in terminal
C2
.
For a central power supply system, only GS-tested,
short- circuit-proof power supply units are authorised. Only allow
voltages/voltage types specifi ed in the “Technical Data” section,
with due regard for the required minimum current. Allowing other
voltages or voltage types will destroy the door intercom. Make sure that
the cables are correctly connected. Incorrect cable connection will also
destroy the door intercom.
Door opener
An electric door opener can be directly connected to the CVS door
intercom. Supply voltage: 12 V DC/max. 1 A.
Caution: do not use door openers requiring a higher operating current, as
this is likely to damage your CVS door intercom (and render your warranty
null and void).
Operation
Set the indoor monitor’s ON/OFF switch
A11
to ON. The LED
A8
lights up
green and the
B5
label on the outdoor monitor also lights up. The device
is now ready for use.
Use switch
A12
on the indoor monitor to select the required ring tone
(1 to 3) or disable the ring tone (0 = OFF). If the ring tone is disabled, the
LED
A8
will light up red. Use volume adjustment
A10
to set the ring tone
volume independently of the general volume. Use volume adjustment
A2
to set the general volume. On the outdoor monitor, set the volume using
volume adjustment
B7
.
If a visitor presses bell
B4
, the indoor monitor and (where fi tted) the
external bell or additional indoor monitor will ring. The visitor can then
speak into the outside monitor and be heard and seen by the person inside
the building. At this point, the person inside the building cannot be heard
by the person outside the building. When using the device for the fi rst time,
adjust the brightness and color
(A13/A14)
.
Button
A5
lights up when connection from the outdoor to the indoor
monitor is enabled. If no buttons are pressed, connection will stop
automatically after approx. 30 seconds.
If talk button
A4
is pressed, the person inside the building can
communicate with the person outside the building. During connection,
talk button
A4
lights up. Press the door open button
A7
to activate the
(optional) door opener.
Press button
A4
or
A5
again to stop communication. If no buttons are
pressed, communication will be automatically interrupted after approx.
2 minutes.
Outside monitoring
Press button
A5
to monitor the outside for 30 seconds.
Extending the system
Storey bell (optional)
Connect a standard button to connecting elements
C9/C10
. If this button
is pressed, the indoor monitor will ring with a preset ring tone which cannot
be adjusted.
External bell (optional)
The CAS external bell (item no. 087613) can be connected to connecting
elements
C7/C8
. The bell features volume adjustment with 3 volume
settings: OFF/quiet/loud.
Safety information
All warranty claims will be null and void in the event of any
damage or loss caused by failure to observe these operating
instructions. We accept no liability for any consequential losses
or damage. We accept no liability for any personal injury or
material damage caused by improper use or by failure to
observe the safety advice. In these cases the guarantee and warranty are
invalidated. For safety and authorisation purposes it is not permitted to
carry out any adaptation or conversion of the device.
Installation
If in any doubt, rather than mounting, connecting or installing the
equipment yourself, contact a qualifi ed technician.
The outdoor unit is designed for fl ush-mounting.
Surface-
mounting is possible using housing (available as an accessory). When
deciding where to install the outdoor monitor, choose a position that is
well protected against the elements, particularly rain. If necessary, use
waterproof housing to protect the device. The camera
(B1)
should face
upwards. Refer to the information on the optimal camera position
(fi g. D)
.
Remove the cover
(fi g. F1)
and install the outdoor monitor according to
fi g. F2
. Fit the seal so that the open ends face downwards. Carefully
remove the cover
(fi g. F3)
to write on the label.
Install the indoor monitor according to
fi g. G
.
Connection
Connect the door intercom according to
fi g. H
.
Connection accessories: see additional sheet.
Video connection
You can connect a television or video recorder to the socket
(A15)
.
Operating elements
Indoor monitor (fi g. A)
1 Microphone
2 Volume adjustment
3 Screen
4 Talk button
5 Monitoring
6 Monitor OFF
7 Open door button
8 LED status indicator
9 Loudspeaker
10 Ring tone volume adjustment
11 ON/OFF switch
12 Ring tone selection/OFF
13 Brightness
14 Color
15 Video connection
Outdoor monitor (fi g. B)
2 to 6 apartments
1 Camera
2 Infrared LED
3 Loudspeaker
4 Bell (2 to 6)
5 Label (2 to 6)
6 Microphone
7 Volume adjustment (at rear)
Power pack (fi g. E) 1 to 6
1 Plug
Connection elements
Indoor monitor (fi g. C)
1 Power supply connector
2 Power supply terminal
3 Outdoor
monitor
connection
4 Outdoor
monitor
connection
5 Floating
relay
contact
(Normally Open)
6 Floating
relay
contact
(Normally Open)
7 External bell
8 External
bell
9 Storey bell button
10 Storey bell button
11 Additional indoor monitor
Outdoor monitor (Fig. D)
Door opener relay positive connector (+)
Door opener relay negative connector (-)
1 Indoor monitor 1 connection <> C3
2 Indoor monitor 1 connection <> C4
1 Indoor monitor 2 connection <> C3
2 Indoor monitor 2 connection <> C4
1 Indoor monitor 3 connection <> C3
2 Indoor monitor 3 connection <> C4
1 Indoor monitor 4 connection <> C3
2 Indoor monitor 4 connection <> C4
1 Indoor monitor 5 connection <> C3
2 Indoor monitor 5 connection <> C4
1 Indoor monitor 6 connection <> C3
2 Indoor monitor 6 connection <> C4
Gutkes GmbH
Postfach 730 308 Fax: +49 (0)511 / 958 58 05
30552 Hannover
Internet: www.gev.de
Germany E-Mail:
CVS video door intercom for 2 to 6 apartments
Connecting a handset (optional)
For more privacy, you can connect a handset to the indoor monitor.
Connect the handset according to additional sheet and
secure. Simply lift up the handset to communicate with the per-
son who has just pressed bell
B4
. The loudspeaker is automatically
disabled when the handset is lifted up. Press the talk button at any
time to conduct a conversation via the loudspeaker and microphone.
CE compliance information
Using the device near electromagnetic high frequency fi elds such as radio
systems, microwaves or mobile phones, or high electrostatic discharge,
can interfere with device operation. Should you encounter problems,
switch the power supply off and on again to restore operation.
Wireless bell (optional)
Terminals
C5/C6
feature a fl oating relay contact (Normally Open). This
contact is closed when bell
B4
is pressed. For example, connect the
GEV CGF 7079 wireless bell. Connect
C5/C6
to contacts 1 + 3 on the
CGF 7079 wireless bell.
Additional video or audio indoor monitor (optional)
Connect an additional video or audio indoor monitor to connector
C11
.
Connection takes place via a cable featuring an RJ11 plug. The additional
monitor features connections for an outdoor bell or the CGF 7079 wireless
bell and video camera.
Troubleshooting - Practical tips
Problem Cause
Solution
No ring tone, LED does not light up
Is the power pack connected?
Connect/check the power pack
Is the power pack faulty?
Faulty device?
Check the device
No ring tone, LED lights up green
Is the cable connecting the indoor and
Check the cable
outdoor monitor incorrectly connected/faulty?
No ring tone, LED lights up red
Is the ring tone volume adjustment set to 0?
Set ring tone adjustment to 1, 2 or 3
Door opener does not work
Wrong type of door opener?
Use a 12 V DC max. door opener
Technical data
Indoor/additional monitor dimensions
approx. W 160 x H 200 x D 46 mm
Outdoor monitor
for 1 or 2 apartments
approx. W 81 x H 152 x D 47 mm
3 apartments
approx. W 81 x H 173 x D 47 mm
4 apartments
approx. W 81 x H 194 x D 47 mm
5 apartments
approx. W 81 x H 215 x D 47 mm
6 apartments
approx. W 81 x H 236 x D 47 mm
Power supply
15 V
Monitor
5.6 inch TFT type
Camera lighting
min. 3 LUX located at < 50 cm
Indoor monitor power supply (without door opener)
Standby mode
approx. 2 W
Operating mode
approx. 11 W
Connection
12
V
/max. 1 A
Distance from indoor to outdoor monitor
70 m max. (0.75 mm
2
)
Distance from indoor monitor to additional monitor
20 m max. (0.45 mm
2
)
Distance from indoor/additional monitor to bell
20 m max. (0.45 mm
2
)
Power pack GPE302 (for each indoor monitor)
Input voltage
230 V ~, 50 Hz
Output voltage
15 V
Rated current
max. 1.5 A
Central power supply
Power supply
15 V
Rated current for 1 apartment
max. 1.5 A
Rated current for 2 apartments
max. 1.6 A
Rated current for 3 apartments
max. 1.7 A
Rated current for 4 apartments
max. 1.8 A
Rated current for 5 apartments
max. 1.9 A
Rated current for 6 apartments
max. 2.0 A
Additional indoor monitor
+ 100 mA per device
We reserve the right to make technical and visual modifi cations without prior notice.
1
2
3
4
5
6
D
GB
F
NL
I
E
S
DK
FIN
RUS
GR
EST
LV
LT
PL
P
RO
SLO
SK
CZ
TR
UA
H