Menus of Inputs/Outputs
continued
Analogue 1...10 input
1. In the Inputs or Outputs menu, press
.
2. The green input fields list the names
of the current analogue inputs. Active inputs
are indicated on the left by a yellow number.
On the right side, the currently measured
value, the associated unit and the graphical
representation are shown. Current alarms are
indicated for each individual input by a mark
at the left side of the graphical representa-
tion.
3. To configure an input, select the green input
field. The menu
Analogue 1...10 Input
ap-
pears.
Analogue 1...10 input parameter
1. If an analogue input has already been parametrised, a corresponding status screen (as shown
here) is displayed.
In this example it is a valve position poti.
2. The parameters for the analogue input are
shown in the display field.
3. To configure the analogue input
press
.
Note
The input sequence corresponds to the order of analogue inputs on the WAGO bus termi-
nal block (max. 5 components, each with 2 of the same types of input from left to right).