![GeoVision GV-POE0812 User Manual Download Page 125](http://html1.mh-extra.com/html/geovision/gv-poe0812/gv-poe0812_user-manual_2216057125.webp)
Web Management
4
4.1.7 Configuration - Loop Protection
This page allows the user to inspect the current Loop Protection configurations,
and possibly change them as well.
General Settings
Enable Loop Protection
Controls whether loop protections is enabled (as a whole).
Transmission Time
The interval between each loop protection PDU sent on each port. valid values
are 1 to 10 seconds.
Shutdown Time
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action shuts down the port). Valid values are 0 to
604800 seconds (7 days). A value of zero will keep a port disabled (until next
device restart).