7 - 38
Genie Z-45/22
Part No. 29487
Service Manual - First Edition
Section 7 - Repair Procedures
no continuity
(infinite
Ω
)
continuity (zero
Ω
)
85 to 95
Ω
no continuity
(infinite
Ω
)
continuity (zero
Ω
)
9-1
Control Relays
How to Test a Single Pole Double
Throw Relay
Electrocution hazard. Contact with
hot or live circuits may result in
death or serious injury. Remove
all rings, watches and other
jewelry.
1 Label and then disconnect all the wiring from
the relay to be tested.
2 Connect the leads from an ohmmeter or
continuity tester to each terminal combination
and check for continuity. Terminals 85 to 86
represent the coil and should not be tested in
any other combination.
d
e
c
a
b
Test
Desired result
terminal 85 to 86
terminal 87 to 87a & 30
terminal 87a to 30
3 Connect 12V DC to terminal 85 and a ground
wire to terminal 86, then test the following
terminal combinations.
Test
Desired result
terminal 87a to 87 & 30
terminal 87 to 30
a
terminal no. 87A
b
terminal no. 85
c
terminal no. 30
d
terminal no. 86
e
terminal no. 87
Relay Panel
Summary of Contents for Z-45/22
Page 1: ...Technical Publications First Edition Part No 29487 Service Manual Z 45 22 ...
Page 121: ...6 3 ...
Page 122: ......
Page 123: ...6 5 ...
Page 124: ...6 6 ...
Page 125: ...6 7 ...
Page 126: ...6 8 ...
Page 127: ......
Page 128: ...6 10 ...
Page 129: ...6 11 ...
Page 130: ...6 12 ...
Page 132: ...Z45 22 Hyd Index ...
Page 133: ...Z45 22 Hyd Index ...
Page 134: ...Z45 22 Hyd Index ...
Page 135: ...Z45 22 Hyd Index ...
Page 136: ...Z45 22 Hyd Index ...
Page 137: ...Z45 22 Hyd Index ...